Care Hawk CH1000 Manual de usuario Pagina 3

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 15
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 2
CareHawk CH1000 Specification
1. SUBMITTALS
1.1. The vendor shall provide the following documentation and service:
1.1.1. Shop drawings: 3 sets. These drawings shall include the manufacturers’
specification sheets, including all component parts.
1.1.2. As-built drawings: 3 sets. They should include up-to-date drawings including
any changes made to the system during installation. Circuit diagrams and
other information necessary for the proper operation and maintenance of the
system shall be included.
1.1.3. All material and/or equipment necessary for the proper operation of the
system, even though not specifically mentioned in the contract documents,
shall be deemed part of this contract.
2. OPERATION AND MAINTENANCE DATA
2.1.1. Submit operation and maintenance data under provisions of Section < >.
2.1.2. Include operator instructions for each required mode of operation, routine
troubleshooting procedures, manufacturer’s operation and maintenance
manual for each item of equipment and accessory, and routine cleaning
methods and materials.
3. QUALIFICATIONS
3.1.1. To establish continuity in manufacturer, system components shall be the
standard product of one manufacturer. Further, an effort shall be made to
establish common sources for equipment of all systems.
3.1.2. The work to be provided under this Section consists of furnishing and installing
all equipment, cabling, and labor required for complete, operable, new
intercommunications systems for the School < >. These systems shall
be referred to as the LOW VOLTAGE SYSTEMS and their supplier as the
LOW VOLTAGE CONTRACTOR.
3.1.3. All empty conduit and power required for the electronic systems shall be
supplied by the electrical contractor as a complete raceway system. Return air
plenum cable shall be used as an option at the electrical contractor’s
discretion. All plenum cable shall meet all applicable local and national codes.
3.1.4. The electrical contractor shall accept bids from pre-qualified low voltage
contractors/suppliers. Prices shall reflect cost of low voltage systems as
completely installed, but the conduit or raceway for these systems should not
be included in this figure. However, if plenum cable is used, it shall be included
All Specifications are Subject to Change CareHawk 3