Project Name M-DCPS MASTER Nov. 2014
Project No. SPECIFICATION GUIDELINES 13745 − 9
1. Micro-processor base programmable by the user through electronic means.
a. Provide a step-by-step guide to enable the user to accomplish the programming
easily and correctly.
b. Master control clocks which are not micro-processor based or that require a
technician to perform the original programming and subsequent program
changes at additional cost to M-DCPS, are not allowed.
2. The programmable master control clock shall be capable of storing and controlling a
minimum of 350 events in non-volatile memory. It shall program and control the
following:
a. The time the event is to occur and whether AM or PM.
b. The selection of any zone or any combination of zones (minimum of 8) where the
event is to occur.
c. A minimum of 6 schedules to allow flexible rearrangement of events to
accommodate special circumstances.
3. The master control clock shall provide for the electronic selection of the following
operational "modes":
a. "TIME": Allow the entry of "present" time display on the clock panel.
b. "DATE": Allow the entry of the current date.
c. "LOAD": Access entry of each element into the clock memory.
d. "EDIT": Allow the sequential display of programs entered, for the purpose of
review, correction, change, or deletion.
e. "SELECT": Allow the activation of zones and schedules.
f. "RUN": The mode for normal operation.
4. The master control clock shall provide pushbuttons for accomplishing the
programming and shall require no special skill or training to perform.
a. By following a simple set of step-by-step instructions, operation of these buttons
shall insert into the clock memory the following elements required for
programming an event:
1) The time it is to occur.
2) AM or PM.
3) The zone or zones it is to occur.
4) The day or days each zone is to be active.
5) The selection of up to 4 schedules required to accommodate normal or
special circumstances.
b. Once the programming for an event has been completed, the entire program
shall be clearly displayed for review before it is entered in the memory.
5. The Master Control Clock shall provide:
a. Digital display.
b. Pushbuttons for manually controlling each zone.
c. A pushbutton for manually activating all zones simultaneously.